PLCDriveHubPLC, HMI, sensors, drives, controllers, robots, and factory automation parts for global industrial buyers.
Excellent Signal Stability Medical Oxygen Sensor O2 Oom204 with CE
Channel Facilities

Excellent Signal Stability Medical Oxygen Sensor O2 Oom204 with CE

This detail page turns one product record into a narrower sourcing decision with clearer category fit, adjacent routes and RFQ-ready context.

Quote on request

Excellent | Applications and Buyer Notes

Excellent is organized as a sourcing-ready Channel Facilities reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-time ques

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
Industrial SensorsBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
Accuracy
meets ISO requirementsBased on visible page data; confirm exact value in the RFQ.
After-sales Service
Online ServicesBased on visible page data; confirm exact value in the RFQ.
Application
Electrical and power distributionBased on visible page data; confirm exact value in the RFQ.
Capacity
0.500kgBased on visible page data; confirm exact value in the RFQ.
Certification
CE, RoHSBased on visible page data; confirm exact value in the RFQ.
Cross interference
meets ISO requirementsBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Product sourcing profile

CategoryChannel Facilities
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Instruments & Meters Analysis Instrument Gas Analyzer Excellent Signal Stability Medical Oxygen Sensor O2 Oom204 with CE US$ pieces US$67.30 10+ pieces Start Order Request Send Inquiry Chat Now Product Details Customization: Available After-salesPLCDriveHub curates RFQ-led product discovery for buyers looking for industrial sensors options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: plc, hmi, sensors, drives, controllers, robots, and factory automation parts sourcing and rfq-ready export supply platform.sensorsexportready

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Industrial Sensors

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Ningxia Maiya Sensor

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

Key specifications

CategoryIndustrial Sensors
Brand
Unitset
Accuracymeets ISO requirements
After-sales ServiceOnline Services
ApplicationElectrical and power distribution
Capacity0.500kg
CategoryIndustrial Sensors
CertificationCE, RoHS
Cross interferencemeets ISO requirements
CustomizationAvailable
Effect of temperature compensation (steady state)between +25 °C and +40 °C: 3 % relative error between 0 °C and +50 °C: 8 % relative error
Electrical interface3 pin (Molex® )
Feature Highlightsdigital
Influence of humidity0.03 % rel. per % RH at 25 °C
Influence of mechanical shock< 1 % relative after a fall from 1 m
Influence of pressureproportional to change in oxygen partial pressure
Linearity error< 3 % relative
Long term output drift< 1 % volume oxygen per month typically <-15 % relative over lifetime
Matched Termssensors, export, ready
MaterialPlastic
Measure Range0-100%Vol
Measurement range0 % … 100 % oxygen (at atmospheric pressure)
Model NO.OOM204
Nominal sensor lifetime≥ 500 000 % volume oxygen hours
Operating humidity0 % … 99 % RH non-condensing
Operating temperature0 °C … +50 °C
OriginGermany
Output difference1.25 mV (between the two channels)
Output in ambient air9 mV … 13.5 mV (each of two channels)
ParameterDetails
PortablePortable
Pressure0.6 bar
Pressure range0.6 bar … 2 bar (ppO2 0 … 1250 mbar O2)
Product TitleExcellent Signal Stability Medical Oxygen Sensor O2 Oom204 with CE
Recommended load≥ 10 kOhms
Recommended storage+5 °C … +15 °C
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Repeatability< 1 % volume O2 at constant temperature and pressure
Response time< 12 s to 90 % of final value
Secure paymentsEvery payment you make on Made-China.com is protected by the platform.
Shipping Cost.
Specification0-100% vol
Storage temperature20 °C … +50 °C
Temperature25 °c
Temperature compensationbuilt-in NTC compensation
TheoryElectrochemical
TrademarkENVITEC
Transport PackageCartons
UseO2 Sensor
Warm-up Time30 Minutes
Warm-up time< 30 minutes, after replacement of sensor
Warranty1 Year
Weight28g
Zero offset voltage< 200 µV in 100 % nitrogen, applied for 5 min

Keyword evidence

Only terms with visible evidence in this listing are shown here.

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Excellent Signal Stability Medical Oxygen Sensor O2 Oom204 with CE sourcing decision brief

This detail page turns one product record into a narrower sourcing decision with clearer category fit, adjacent routes and RFQ-ready context.

Category
Industrial Sensors
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Product detail to shortlist decision
Primary compare
Category, Brand, Unit
Record focus
Excellent Signal Stability Medical Oxygen Sensor O2 Oom204 With Ce
Category focus
Channel Facilities
Buyer checklist
  • Category fit: Confirm whether the product belongs to the right category and nearby application path before outreach.
  • Specification depth: Review the visible specifications and convert missing fields into a clearer RFQ requirement set.
  • Route expansion: Use adjacent category, solution and procurement routes before settling on one detail page.
How should buyers use this detail page?

Use the detail page as a product-fit checkpoint. Confirm category placement, visible specifications and adjacent sourcing paths before sending an RFQ.

What should buyers compare first?

Compare the visible specifications, category fit and the nearest application or solution routes before asking for supplier options.

PLCDriveHub related sourcing paths

PLCDriveHub procurement phrases

PLCDriveHub project-fit checks

Application Confirm Application before comparing offers or moving the inquiry forward.
Country Confirm Country before comparing offers or moving the inquiry forward.
Capacity Confirm Capacity before comparing offers or moving the inquiry forward.
Material Confirm Material before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PLCDriveHub related product samples

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions