PLCDriveHubPLC, HMI, sensors, drives, controllers, robots, and factory automation parts for global industrial buyers.
Honeywell Xnx Transmitter Fixed Gas Detector Co H2s H2 with ATEX Certificate
Port And Wharf Equipment

Honeywell Xnx Transmitter Fixed Gas Detector Co H2s H2 with ATEX Certificate

This detail page turns one product record into a narrower sourcing decision with clearer category fit, adjacent routes and RFQ-ready context.

Quote on request

Honeywell | Applications and Buyer Notes

Honeywell is organized as a sourcing-ready Port And Wharf Equipment reference. The page combines visible product or company data with structured procurement cues so buyers can compare application fit, specifications, quantity, quality requirements and lead-tim

Applications

  • Initial shortlist building for related product or supplier options.
  • Specification and application fit review before bulk purchasing.
  • Category, keyword and detail-page comparison before sending an RFQ.

Key specifications

Category
DetailsBased on visible page data; confirm exact value in the RFQ.
Brand
HoneywellBased on visible page data; confirm exact value in the RFQ.
Unit
setBased on visible page data; confirm exact value in the RFQ.
4-20mA Signal Accuracy
±1% Full ScaleBased on visible page data; confirm exact value in the RFQ.
After-sales Service
Online ServiceBased on visible page data; confirm exact value in the RFQ.
Alarm Type
Audible Visual, VibratingBased on visible page data; confirm exact value in the RFQ.
Application
Electrical and power distributionBased on visible page data; confirm exact value in the RFQ.
Capacity
3.000kgBased on visible page data; confirm exact value in the RFQ.

Buyer tips

  • State quantity range and split-delivery needs before price comparison.
  • Add certification, material or inspection standards when they affect acceptance.
  • For time-sensitive projects, include target arrival date and destination.
  • For special applications, describe operating condition, installation environment and duty cycle.

FAQ

What should buyers confirm first?

Confirm application, specification, quantity, destination and lead-time requirements before comparing offers.

Can buyers inquire when specs are incomplete?

Yes. Add model, material, size, use case and inspection needs in the RFQ to make replies comparable.

How should this listing be evaluated?

Check title, category, specifications and related keywords against the actual sourcing requirement.

Source mix: ugc

Product sourcing profile

CategoryPort And Wharf Equipment
Inquiry workflowPlatform RFQ workflow
AvailabilityInquiry required
Updated2026-05-04

Product introduction

Home Instruments & Meters Analysis Instrument Gas Analyzer Honeywell Xnx Transmitter Fixed Gas Detector Co H2s H2 with ATEX Certificate US$2, pieces US$ + pieces Start Order Request Send Inquiry Chat Now Product Details Customization: AvailabAutomationPartSupply curates RFQ-led product discovery for buyers looking for plc, hmi and controllers options. The page is organized around specification review, application fit, and inquiry-ready comparison.When evaluating this product, buyers should confirm application fit, required performance range, installation environment, lead time, documentation, and whether the supplier can support OEM or project quotations. Current vertical focus: plc, hmi, sensors, drives, controllers, robots, and factory automation parts sourcing and rfq-ready export supply platform.controllerssensorsexportvision

Selection and RFQ points

Review material fit, application context, alternatives and RFQ detail before comparing related product paths.

Material fit Port Wharf Equipment

Confirm material, size, finish, tolerance and processing needs before price comparison.

Application fit application, operating environment and usage frequency

Add the target application and operating context so related products can be compared correctly.

Alternative path Hmi Controllers

Use nearby materials, equipment types or category pages when this record is close but not exact.

RFQ detail Quantity, destination, timing

Include quantity, destination, target delivery window, packaging and any technical constraints.

Key specifications

CategoryPLC, HMI and Controllers
Brand
Unitset
4-20mA Signal Accuracy±1% Full Scale
After-sales ServiceOnline Service
Alarm TypeAudible Visual, Vibrating
ApplicationElectrical and power distribution
BrandHoneywell
Capacity3.000kg
CategoryDetails
CertificationCE, ATEX
Current OutputFully configurable isolated 4-20mA & HART® output module providing current sink, current source and isolated modes of operation
CustomizationAvailable
CustomizedNon-Customized
DescriptionLel Leak Gas Detector
Dimensions160mm × 197mm × 114mm (6.1" × 7.8" × 4.5")
Entries5 configurable cable entries (2 right, 2 left, 1 bottom). Entry size M25 for ATEX/Ex versions or ½"NPT for UL/CSA certified versions
Feature Highlightsstainless steel, digital
Functions Supported by HART®Gas reading
GasCO
Humidity Range0%-95% Percent
IP RatingIP66 in accordance with EN60529:1992, NEMA 4X
Input Voltage RangeEC and mV versions: 16 to 32Vdc, IR version: 18 to 32 Vdc (24Vdc nominal)
Matched Termscontrollers, sensors, export, vision
MaterialHousing: 5-coat marine finish painted aluminium alloy or 316 stainless steel
Max Power ConsumptionXNX EC (Poison): 6.2 watts
Measuring Range0-5000ppm
Model NO.honeywell xnx
MountingSurface mount via integral mounting lugs. Optional pipe mounting kit suitable for Ø100mm to 150mm (3/4" to 6") pipe. Optional ceiling mounting bracket
Operating Humidity0-99%RH
Operating Pressure90-110 kPa
Operating Temperature40°C to +65°C-40°F to +149°F
OriginAmerican
PortableNon Portable
Pressure110 kpa
Product TitleHoneywell Xnx Transmitter Fixed Gas Detector Co H2s H2 with ATEX Certificate
Refund policyClaim a refund if your order doesn't ship, is missing, or arrives with product issues.
Secure paymentsEvery payment you make on Made-China.com is protected by the platform.
Sensor RangeVoc-5000ppm
Shipping Cost.
Specification255 x 76 x 64 mm
StandardsATEX II 2g Eex Ia Iic T4
Storage Conditions40°C to 75°C-40°F to 167°F), 0-99% non-condensing
Sub-CategoryPremium-Gas
Temperature40°c
TerminalsCage style pluggable with retaining screws for wire diameter 0.5mm² to 2.5mm² (approx. 20AWG to 14AWG)
TheoryPhotoionization Detector
Trademarkhoneywell
Transport PackageCartons
TypeElectrochemical Gas Analyzer
UseGas Leak Detect
Voltage24v
Voltage - RatedOriginal
Warranty1year
Weight (Approx.)Aluminium alloy: 2.8kg (6.2lb), 316 stainless steel: 5kg (11lbs)

Product sourcing keywords

These terms come from the title, visible copy and specifications, and link into matching aggregate pages.

Related keyword paths

Grouped by the product keyword that generated the related path.

SOURCING DECISION BRIEF

Honeywell Xnx Transmitter Fixed Gas Detector Co H2s H2 with ATEX Certificate sourcing decision brief

This detail page turns one product record into a narrower sourcing decision with clearer category fit, adjacent routes and RFQ-ready context.

Category
PLC, HMI and Controllers
Price status
Quote on request
Inquiry model
Structured product RFQ with quantity, destination and technical requirements.
Availability
Confirm by inquiry
Sourcing lens
Product detail to shortlist decision
Primary compare
Category, Brand, Unit
Record focus
Honeywell Xnx Transmitter Fixed Gas Detector Co H2s H2 With Atex Certificate
Category focus
Port And Wharf Equipment
Buyer checklist
  • Category fit: Confirm whether the product belongs to the right category and nearby application path before outreach.
  • Specification depth: Review the visible specifications and convert missing fields into a clearer RFQ requirement set.
  • Route expansion: Use adjacent category, solution and procurement routes before settling on one detail page.
How should buyers use this detail page?

Use the detail page as a product-fit checkpoint. Confirm category placement, visible specifications and adjacent sourcing paths before sending an RFQ.

What should buyers compare first?

Compare the visible specifications, category fit and the nearest application or solution routes before asking for supplier options.

PLCDriveHub related sourcing paths

PLCDriveHub procurement phrases

PLCDriveHub project-fit checks

Application Confirm Application before comparing offers or moving the inquiry forward.
Country Confirm Country before comparing offers or moving the inquiry forward.
Capacity Confirm Capacity before comparing offers or moving the inquiry forward.
Material Confirm Material before comparing offers or moving the inquiry forward.
Application route Use Application to compare adjacent options instead of relying on one broad title match.
Country route Use Country to compare adjacent options instead of relying on one broad title match.

PLCDriveHub related product samples

Procurement notes

If visible specifications are still thin, add model, material, interface, quantity, application fit, destination and target lead time before comparing quotes.

Next sourcing actions